One 250-watt lamp in a warm kitchen and the same lamp in an unheated shed in March are two different heating systems. In the first, chicks spread out to the walls; in the second, they huddle in a pile and by morning a few are stuck under the rest. Brooder heat isn’t calculated “per chick” but adjusted for how cold it is around the brooder. Here’s how to choose a heat source and how many you need.
What to heat with
| Heater | Power | Pros | Cons |
|---|---|---|---|
| Infrared heat lamp | 100–250 W | Cheap, easy to adjust by height | Light around the clock, bulbs break, the most common cause of brooder fires |
| Ceramic heat emitter | 100–250 W | No light, lasts for years | The housing gets very hot; needs a ceramic socket and reflector |
| Heat plate (“electric hen”) | 20–60 W | Barely heats the air, can’t burn, chicks sleep in the dark | More expensive; one plate isn’t enough in a cold room |
| Gas brooder | from 2–3 kW | Heats hundreds of chicks, doesn’t depend on light | Needs ventilation: burning gas releases moisture and carbon dioxide |
| Floor or film heating | by area | Dry litter, even warmth | Expensive to install, slow to respond |
How many heaters you need
Lamp makers give a rule of thumb: one 250-watt lamp heats about 75 chicks if the room is no colder than +10 °C (50 °F). The colder the room, the fewer chicks per lamp.
| Room temperature | Chicks per 250 W lamp | 50 chicks | 100 chicks | 300 chicks |
|---|---|---|---|---|
| +18 °C (64 °F) and above (house, warm annex) | up to 100 | 1 lamp, 150–250 W | 1–2 lamps | 3 lamps |
| +10…+17 °C (50–63 °F) | about 75 | 1 lamp | 2 lamps | 4 lamps |
| 0…+10 °C (32–50 °F, a shed in spring) | 40–50 | 1–2 lamps | 2–3 lamps | 6–7 lamps or a gas brooder |
| Below 0 °C (32 °F) | — | Insulate and stop drafts first, otherwise no number of lamps will be enough | ||
Heat plates are sized by area: a 30 × 30 cm (12 × 12 in) plate covers about 15–20 day-old chicks, half that by week three. Makers print the capacity on the box; buy with headroom, because grown chicks no longer fit underneath. In a cold shed, a plate is paired with one lamp or placed in an insulated box.
Even if one lamp would do, use two smaller ones. Bulbs most often burn out at night, and the remaining one will keep the chicks from chilling until morning.
How high to hang it
In week one, a 250-watt lamp hangs 40–50 cm (16–20 in) above the litter and goes up 5–8 cm (2–3 in) each week. 100–150-watt lamps hang lower, at 30–35 cm. The exact height is set not by centimeters but by a thermometer at chick level and by the chicks’ behavior: spread evenly around the edge of the warm spot — good. How temperature changes by day is covered in the first two weeks article.
Thermostat
A thermostat with a remote probe switches the heat on and off by itself, so the brooder doesn’t overheat in the afternoon when the sun warms the shed.
- The probe goes at chick level, at the edge of the warm spot — not right under the heater and not by the wall.
- Yes with ceramic emitters and plates, careful with lamps. A lamp that keeps going on and off disrupts the chicks’ light. It’s easier to adjust a lamp by height and put the thermostat on a ceramic emitter.
- Relay rating with headroom. Two 250 W lamps are 500 W; choose a thermostat rated for at least 10 A.
- A 1 °C switching band. Narrower, and the relay clicks constantly; wider, and the chicks swing between chilled and overheated.
What the electricity costs
| Heater | kWh per day | Over 3 weeks |
|---|---|---|
| 250 W lamp, around the clock | 6 | about 126 |
| 150 W ceramic emitter on a thermostat (on ~60% of the time) | about 2.2 | about 45 |
| 40 W heat plate | about 1 | about 20 |
Multiply by your tariff. With three or four batches a year, the difference between a lamp and a plate often pays for the plate in its first season.
Common mistakes
- the lamp in the center of the brooder — chicks have nowhere to get away from the heat;
- a thermometer on the wall at head height — it shows the air under the ceiling, not at the chicks;
- the heat switched on the day the chicks arrive — the litter and floor are still cold: switch on a day ahead;
- a lamp hanging by its cord with no guard — see the fire safety article.
Brooder layouts with dimensions are in DIY brooder plans, and keeping the heat in a cold shed in the insulation article.
Heating in your records