Every spring the news tells the same story: a shed burned down with the chicks inside, cause — a heat lamp. The lamp fell into the litter, or water splashed on it and the bulb burst, or a plastic socket overheated, or dust on the reflector caught fire. Nearly all of these fires can be prevented with cheap measures. Below is a checklist worth going through before every batch.
Why it catches fire
| Cause | How it happens |
|---|---|
| The lamp fell | It hung by its own cord or a single spring clamp, the cord wore through, a chick or a cat knocked it |
| The bulb burst | Water from a drinker or the roof hit the hot glass, and red-hot shards fell into the shavings |
| The socket melted | A plastic socket rated for 60–100 W holding a 250 W bulb |
| An extension cord | A thin cord or power strip under load for days heats up and the contact burns |
| Dust | Dust and down settle on the hot reflector and smolder |
| Too close | The lamp less than 30–40 cm (12–16 in) from litter, cardboard or the brooder wall |
How to hang a lamp
- A chain or cable, not the cord. The cord only powers the lamp; the chain carries the weight.
- A second fastening. If the lamp is on a clamp, back it up with a chain — clamps slip.
- A guard under the bulb, so shards or the lamp itself can’t drop into the litter.
- At least 30–40 cm (12–16 in) clearance from litter, walls, the brooder lid and anything that burns. For ceramic emitters, follow the instructions — their housing gets hotter.
- Not over a drinker: splashes and steam are the main enemies of hot glass.
A heat plate (“electric hen”) runs at 20–60 W and its surface is warm, not red-hot. If the brooder stands in a wooden shed next to hay, it’s the safest option. Heat sources are compared in the brooder heating article.
Wiring
- A ceramic socket rated for at least the bulb’s wattage.
- No power strips or thin cords. A dedicated outlet or fixed wiring in conduit, sized for the load.
- A residual-current device (RCD or GFCI) on the poultry house circuit: in a damp shed with metal drinkers it protects against both fire and electric shock.
- Once a week, feel the plug and outlet. Warm to the touch means a poor contact — replace it at once.
- Cords out of reach of birds and rodents, not sagging down to the litter.
Alarm and extinguishing
- A temperature sensor with phone alerts warns you both of overheating and of a lamp going out. An ordinary smoke detector in a dusty shed often gives false alarms, so heat detectors are more common in poultry houses.
- A fire extinguisher — dry powder, by the door outside, not deep inside the shed.
- Hay, straw and spare bedding stored separately, not next to the brooder.
Checklist before every batch
- Chain and second fastening in place, guard intact.
- Socket is ceramic, with no dark marks or cracks.
- Reflector and bulb free of dust.
- At least 30–40 cm to litter, walls and lid.
- Drinkers not under the lamp.
- Outlet, plug and cord intact and not warm; no extension cords.
- RCD checked with its test button.
- Temperature sensor working, extinguisher by the door.
How to set up the whole brooder, with dimensions and zones, is in DIY brooder plans. What to do when the power goes and ventilation stops is in the emergency plan article.
Keeping an eye on the brooder
In EggPulse brooder temperature is logged in the climate section and mortality in the batch log. If the records show the temperature dropping at night and mortality rising in the morning, it’s time for a second heat source or a sensor with alerts — before something worse happens.